آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific

آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientificآنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific
برند:

آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific

لطفا جهت مطالعه توضیحات بیشتر این محصول به لینک سایت زیر مراجعه نمایید:

https://www.thermofisher.com/order/catalog/product/ER0342?SID=srch-srp-ER0342

Eco57I (AcuI) (5 U/µL) Catalog number: ER0342 Size: 1,000 units

Eco57I (AcuI) (5 U/µL) Catalog number: ER0341 Size: 200 units

واردات محصول فوق سه هفته الی یک ماه زمان بر خواهد بود

ریال

تحویل اکسپرس
پشتیبانی 24 ساعته
پرداخت در محل
7 روز ضمانت بازگشت
ضمانت اصل بودن کالا

توضیحات محصول

آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific

آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific

Catalog Number: ER0341

Unit Size: 200 Units

Catalog Number: ER0342

Unit Size: 1000 Units

5′ C T G A A G N16 3′
3′ G A C T T C N14 5′


Thermo Scientific Eco57I (AcuI) restriction enzyme recognizes CTGAAG(16/14)^ sites and cuts best at 37°C in G (+SAM) buffer. See Reaction Conditions for Restriction Enzymes for a table of enzyme activity, conditions for double digestion, and heat inactivation for this and other restriction enzymes. Note: Also available as a FastDigest enzyme for rapid DNA digestion. Isoschizomers: AcuI.

Thermo Scientific conventional restriction endonucleases are a large collection of high quality restriction enzymes, optimized to work in one of the buffers of the Five Buffer System. In addition, the universal Tango buffer is provided for convenience in double digestions. All of the enzymes exhibit 100% activity in the recommended buffer and reaction conditions. To ensure consistent performance, Thermo Scientific restriction enzyme reaction buffers contain premixed BSA, which enhances the stability of many enzymes and binds contaminants that sent in DNA preparations.

Features

• Superior quality—stringent quality control and industry leading manufacturing process
• Convenient color-coded Five Buffer System
• Includes universal Tango buffer for double-digestions
• BSA premixed in reaction buffers
• Wide selection of restriction endonuclease specificities

Applications

• Molecular cloning
• Restriction site mapping
• Genotyping
• Southern blotting
• Restriction fragment length polymorphism (RFLP)
• SNP

Note: Eco57I requires only Mg2+ for its activity, but is stimulated by S-adenosylmethionine. 0.01 mM S-adenosylmethionine gives a 100-fold increase in Eco57I activity. Still, complete cleavage of some substrates with Eco57I is difficult to achieve Eco57I concentration is determined by the maximum cleavage level achieved when no change in the fragmentation pattern is observed with further enzyme increase. Low salt, high glycerol (> 5%) concentrations, pH > 8.0 or a large excess of enzyme may result in star activity. Eco57I may remain associated with the cleaved DNA. This may cause DNA band shifting during electrophoresis. To avoid atypical DNA band patterns, use the 6X DNA Loading Dye & SDS Solution for sample preparation or heat the digested DNA in the presence of SDS prior to electrophoresis.For methylation sensitivity, refer to product specifications.

Specifications
5U/µL
Concentration
Not Dam Methylation-Sensitive,
Not Dcm Methylation-Sensitive,
Not CpG Methylation-Sensitive
Methylation Sensitivity
Eco57I (AcuI)
Enzyme
10X Buffer G
Compatible Buffer
YesSensitive to Heat Inactivation
37°C
Optimal Reaction Temperature
YesType IIS RE
1000U
Quantity
Restriction Enzyme
Product Type
Scarless cloning
Research Category

آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific

بررسی تخصصی

آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific
سایر ویژگی‌ها
یونیت مورد نظر را انتخاب کنید
1000

200

دیدگاه کاربران

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “آنزیم Eco57I (AcuI) (5 U/µL) | کمپانی Thermo Fisher Scientific”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *