آنزیم MnlI (10 U/µL) | کمپانی Thermo Fisher Scientific
آنزیم MnlI (10 U/µL) | کمپانی Thermo Fisher Scientific
لطفا جهت مطالعه توضیحات بیشتر این محصول به لینک سایت زیر مراجعه نمایید:
https://www.thermofisher.com/order/catalog/product/ER1072?SID=srch-srp-ER1072
MnlI (10 U/µL) catalog number: ER1072 Size: 1,500 units
MnlI (10 U/µL) catalog number: ER1071 Size: 300 units
واردات محصول فوق سه هفته الی یک ماه زمان بر خواهد بود
1 ریال
توضیحات محصول
آنزیم MnlI (10 U/µL) | کمپانی Thermo Fisher Scientific
Catalog Number: ER1071
Unit Size: 300 Units
Catalog Number: ER1072
Unit Size: 1500 Units
5′ | C | C | T | C | N7 | ↓ | 3′ | |||
3′ | G | G | A | G | N6 | ↑ | 5′ |
Thermo Scientific MnlI restriction enzyme recognizes CCTC(7/6)^ sites and cuts best at 37°C in G buffer. See Reaction Conditions for Restriction Enzymes for a table of enzyme activity, conditions for double digestion, and heat inactivation for this and other restriction enzymes. Note: Also available as a FastDigest enzyme for rapid DNA digestion.
Thermo Scientific conventional restriction endonucleases are a large collection of high quality restriction enzymes, optimized to work in one of the buffers of the Five Buffer System. In addition, the universal Tango buffer is provided for convenience in double digestions. All of the enzymes exhibit 100% activity in the recommended buffer and reaction conditions. To ensure consistent performance, Thermo Scientific restriction enzyme reaction buffers contain premixed BSA, which enhances the stability of many enzymes and binds contaminants that may be present in DNA preparations.
Features
• Superior quality—stringent quality control and industry leading manufacturing process
• Convenient color-coded Five Buffer System
• Includes universal Tango buffer for double-digestions
• BSA premixed in reaction buffers
• Wide selection of restriction endonuclease specificities
Applications
• Molecular cloning
• Restriction site mapping
• Genotyping
• Southern blotting
• Restriction fragment length polymorphism (RFLP)
• SNP
Note: MnlI produces DNA fragments that have a single-base 3 extension which are more difficult to ligate than blunt-ended fragments. MnlI may remain associated with the cleaved DNA. This may cause DNA band shifting during electrophoresis. To avoid atypical DNA band patterns, use the 6X DNA Loading Dye & SDS Solution for sample preparation or heat the digested DNA in the presence of SDS prior to electrophoresis. For methylation sensitivity, refer to product specifications.
Specifications | |
---|---|
10U/μL | Concentration |
Not Dam Methylation-Sensitive, Not Dcm Methylation-Sensitive, Not CpG Methylation-Sensitive | Methylation Sensitivity |
MnlI | Enzyme |
10X Buffer G | Compatible Buffer |
Yes | Sensitive to Heat Inactivation |
37°C | Optimal Reaction Temperature |
No | Type IIS RE |
1500U | Quantity |
Restriction Enzyme | Product Type |
Scarless cloning | Research Category |
بررسی تخصصی
سایر ویژگیها | ||
---|---|---|
|
دیدگاهها
هیچ دیدگاهی برای این محصول نوشته نشده است.